Command Description Refer To
*CLS Clears the status registers Section 8.4.12
*ESE? Returns the Event Status Enable Register Section 8.4.12
*ESE <num>|MIN|MAX|DEF Sets the Event Status Enable Register Section 8.4.12
*ESR? Returns the Event Status Register Section 8.4.12
*IDN? Returns the instrument identification string that indicates
the manufacturer, model number, serial number, and firm
-
ware version
Section 8.4.8
*OPT? Returns a list of installed input card types Section 8.4.8
*RST Sets the instrument operating parameters to defined
conditions
Section 8.4.8
*SRE? Returns the Service Request Enable Register Section 8.4.12
*SRE <num>|MIN|MAX|DEF Sets the Service Request Enable Register Section 8.4.12
*STB? Returns the Status Byte Register Section 8.4.12
*TST? Performs a self-test and reports any errors that are found Section 8.4.12
CALCulate:AVERage:CLEar Clears the statistical functions for all channels Section 8.4.1
CALCulate<chn>:AVERage<n>:DATA? Returns the value of a statistical calculation for the speci-
fied channel
Section 8.4.1
CALCulate:AVERage<n>:TYPE? Returns the keyword for the specified calculation type
number
Section 8.4.1
CALCulate<chn>:CONVert:CATalog? Returns a list of conversion types available for the speci-
fied channel
Section 8.4.4
CALCulate<chn>:CONVert:COPY<dest chn>|ALL Copies the conversion type, sub-ranges (ITS-90), serial
number, and characterization coefficients from one chan
-
nel to another
Section 8.4.4
CALCulate<chn>:CONVert:NAMe? Returns the name of the selected conversion type for the
specified channel
Section 8.4.4
CALCulate<chn>:CONVert:NAMe <conv> Sets the conversion type by name for the specified
channel
Section 8.4.4
CALCulate<chn>:CONVert:PARameter:CATalog? Returns the names of the probe characterization parame
-
ters used with the selected conversion type for the speci
-
fied channel
Section 8.4.4
CALCulate<chn>:CONVert:PARameter:VALue?
[<param>|ALL]
Returns the value for the specified or All conversion pa
-
rameters for the specified channel
Section 8.4.4
CALCulate<chn>:CONVert:PARameter:VALue
<param>,<num>[,< param>,<num>...]
Sets the value of one or more conversion parameters for
the specified channel number
Section 8.4.4
CALCulate:CONVert:PRINt [<chn>|ALL [,<port>]] Returns the conversion parameters for the specified
channel
Section 8.4.4
CALCulate<chn>:CONVert:SNUMber? Returns the probe serial number for the specified channel Section 8.4.4
CALCulate<chn>:CONVert:SNUMber <seri> Sets the probe serial number for the specified channel Section 8.4.4
CALCulate<chn>:CONVert:TEST? <res>|<volt> Tests the temperature conversion for the specified channel Section 8.4.4
81
8 Digital Communications Interface
Interface Commands