Emerson 00809-0100-4102 Sleep Apnea Machine User Manual


 
125
Reference Manual
00809-0100-4102, Rev AA
Appendix A: Reference Data
May 2013
Specifications and Reference Data
Standard
WP5 Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
Options (Include with selected model number)
Transmitter Body / Bolt Material
Expanded
GT High Temperature (850 °F / 454 °C)
Temperature Sensor
Expanded
RT
(2)
Thermowell and RTD
Optional Connection
Standard Standard
G1 DIN 19213 Transmitter Connection
Pressure Testing
Expanded
P1
(3)
Hydrostatic Testing with Certificate
Special Cleaning
Expanded
P2 Cleaning for Special Services
PA Cleaning per ASTM G93 Level D (Section 11.4)
Material Testing
Expanded
V1 Dye Penetrant Exam
Material Examination
Expanded
V2 Radiographic Examination
Flow Calibration
Expanded
WD
(4)
Discharge Coefficient Verification
Special Inspection
Standard Standard
QC1 Visual & Dimensional Inspection with Certificate
QC7 Inspection and Performance Certificate
Material Traceability Certification
Standard Standard
Q8 Material Traceability Certification per EN 10204:2004 3.1
Code Conformance
Expanded
J2
(5)
ANSI/ASME B31.1
J3
(5)
ANSI/ASME B31.3
J4
(5)
ANSI/ASME B31.8
Materials Conformance
Expanded
J5
(6)
NACE MR-0175 / ISO 15156
Country Certification
Standard Standard
J6 European Pressure Directive (PED)
Expanded
J1 Canadian Registration
Table A-11. Rosemount 2051CFP Integral Orifice Flowmeter Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.