Specifications and Reference Data
Surface Finish
Standard Standard
Q16 Surface finish certification for sanitary remote seals ★
Toolkit Total System Performance Reports
Standard Standard
QZ Remote Seal System Performance Calculation Report ★
Typical Model
Number:
2051T G 5 X 2A 2 1 P WA3 WP5 B4 M5
(1) Wireless output (code X) available in absolute measurement type (code A) with only range 1-5, with 1/2 14-NPT process connection (code 2B) and housing code P.
(2) 2051TG lower range limit varies with atmospheric pressure.
(3) Wireless output (code X) only available in G1/2 A DIN 16288 Male process connection (code 2C) with range 1-4, 316L SST isolating diaphragm 9code 2), silicone fill fluid
(code 1), and housing code (code P).
(4) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain
materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(5) “Assemble-to” items are specified separately and require a completed model number.
(6) Not available with Alloy C-276 isolator (3 code), tantalum isolator (5 code), all cast C-276 flanges, all plated CS flanges, all DIN flanges, all Level flanges, assemble-to
manifolds (S5 and S6 codes), assemble-to seals (S1 and S2 codes), assemble-to primary elements (S3 and S4 codes), surface finish certification (Q16 code), and remote seal
system report (QZ code).
(7) Not available with fieldbus (output code F) or Profibus protocols (output code W).
(8) Not valid with Alternate Process Connection S5.
(9) High Performance Option includes 0.04% Reference Accuracy. See
Performance Specifications for details.
Table A-7. 2051T In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.