Emerson 00809-0100-4102 Sleep Apnea Machine User Manual


 
124
Reference Manual
00809-0100-4102, Rev AA
Appendix A: Reference Data
May 2013
Specifications and Reference Data
0250 0.250-in. (6.35 mm) for 1-in. Pipe
0345 0.345-in. (8.76 mm) for 1-in. Pipe
0500 0.500-in. (12.70 mm) for 1-in. Pipe
0630 0.630-in. (16.00 mm) for 1-in. Pipe
0800 0.800-in. (20.32 mm) for 1-in. Pipe
0295 0.295-in. (7.49 mm) for 1 1/2-in. Pipe
0376 0.376-in. (9.55 mm) for 1 1/2-in. Pipe
0512 0.512-in. (13.00 mm) for 1 1/2-in. Pipe
0748 0.748-in. (19.00 mm) for 1 1/2-in. Pipe
1022 1.022-in. (25.96 mm) for 1 1/2-in. Pipe
1184 1.184-in. (30.07 mm) for 1 1/2-in. Pipe
Expanded
0010 0.010-in. (0.25 mm) for 1/2-in. Pipe
0014 0.014-in. (0.36 mm) for 1/2-in. Pipe
0020 0.020-in. (0.51 mm) for 1/2-in. Pipe
0034 0.034-in. (0.86 mm) for 1/2-in. Pipe
Transmitter Connection Platform
Standard Standard
D3 Direct-mount, 3-Valve Manifold, SST
D5 Direct-mount, 5-Valve Manifold, SST
R3 Remote-mount, 3-Valve Manifold, SST
R5 Remote-mount, 5-Valve Manifold, SST
Expanded
D4 Direct-mount, 3-Valve Manifold, Alloy C-276
D6 Direct-mount, 5-Valve Manifold, Alloy C-276
D7 Direct-mount, High Temperature, 5-Valve Manifold, SST
R4 Remote-mount, 3-Valve Manifold, Alloy C-276
R6 Remote-mount, 5-Valve Manifold, Alloy C-276
Differential Pressure Ranges
Standard Standard
1 0 to 25 in H
2
O (0 to 62,3 mbar)
2 0 to 250 in H
2
O (0 to 623 mbar)
3 0 to 1000 in H
2
O (0 to 2,5 bar)
Transmitter Output
Standard Standard
X Wireless
Transmitter Housing Material Conduit Entry Size
Standard Standard
P Engineered Polymer N/A
Transmitter Performance Class
Standard Standard
1 up to ±2.25% flow rate accuracy, 8:1 flow turndown, 5-year stability
Wireless options (Requires wireless option code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard
WA3 User Configurable Transmit Rate, 2.4GHz WirelessHART
Antenna and SmartPower
Table A-11. Rosemount 2051CFP Integral Orifice Flowmeter Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.