Emerson Process Management IB106-340 Oxygen Equipment User Manual


 
Instruction Manual
IB-106-340 Rev. 2.4
April, 2001
1-10 Description and Specifications Rosemount Analytical Inc. A Division of Emerson Process Management
Oxymitter 4000
1-6 SPECIFICATIONS
Oxymitter 4000
O
2
Range:
Standard .................................................. 0 to 10% O
2
0 to 25% O
2
0 to 40% O
2
(via HART)
Accuracy ............................................................. ±0.75% of reading or 0.05% O
2
, whichever is greater
System Response to Calibration Gas ................ Initial response in less than 3 seconds T90 in less than
8 seconds
Temperature Limits:
Process .................................................... 32° to 1300°F (0° to 704°C) up to 2400°F (1300°C)
with optional accessories
Electronics ............................................... -40° to 185°F (-40° to 85°C)
Operating temperature of electronics inside of instru-
ment housing, as measured by a HART communicator
or Rosemount Asset Management Solutions software.
Probe Lengths .................................................... 18 in. (457 mm)
3 ft (0.91 m)
6 ft (1.83 m)
9 ft (2.74 m)
12 ft (3.66 m)
Mounting and Mounting Position ........................ Vertical or horizontal
Spool pieces are available, P/N 3D39761G02, to offset
transmitter housing from hot ductwork.
Materials:
Probe ....................................................... Wetted or welded parts - 316L stainless steel
Non-wetted parts - 304 stainless steel, low-copper
aluminum
Electronics Enclosure .............................. Low-copper aluminum
Calibration .......................................................... Manual, semi-automatic, or automatic
Calibration Gas Mixtures Recommended .......... 0.4% O
2
, Balance N
2
8% O
2
, Balance N
2
Calibration Gas Flow .......................................... 5 scfh (2.5 l/m)
Reference Air ..................................................... 2 scfh (1 l/m), clean, dry, instrument-quality air
(20.95% O
2
), regulated to 5 psi (34 kPa)
Electronics .......................................................... NEMA 4X, IP66 with fitting and pipe on reference ex-
haust port to clear dry atmosphere
Electronic Noise ................................................. Meets EN 50082-2 Generic Immunity Std. Part II.
Includes EN 61000-4-2 for Electrostatic Discharge
4 KV contact, 8 KV in air
Includes IEC 801-4 for fast transients; 2 KV on power
supply and control lines
Line Voltage ....................................................... 90-250 VAC, 50/60 Hz. No configuration necessary
3/4 in. - 14 NPT conduit port