SECTION 3—SAFETY INSPECTION/TROUBLESHOOTING
Pronto® Series 24 Part No. 1125075
5 E05 Left Park Brake
Fault
00 Left Park Brake Drive-Time
Test Failed
Check the left park brake connections and
cable.
01 Left Park Brake Output
Enabled When Wheelchair
Idle
02 Left Park Brake Output Did
not Enable When Entering
Drive Mode
03 Left Park Brake fault during
power-up testing
04 Left park brake feedback low
during drive (park brake
short)
6 E06 Right Park Brake
Fault
00 Right Park Brake Drive-Time
Test Failed
Check the right park brake connections
and cable.
01 Right Park Brake Output
Enabled When Wheelchair
Idle
02 Right Park Brake Output Did
not Enable When Entering
Drive Mode
03 Right Park Brake fault during
power-up testing
04 Right park brake feedback
low during drive (park brake
short)
7 E07 Remote Fault 00 Local SR Fault (CPU,
EEPROM, etc.)
Check the communications bus, connec-
tions and wiring. Replace the remote.
01 Joystick fault at the remote
02 Speed pot fault at the remote
NUMBER OF FLASHES
DIAGNOSTICS CODE
ERROR CODE
DESCRIPTION
SUB CODE*
DETAILS OF
ERROR CODE
POSSIBLE