Emerson 4000 Oxygen Equipment User Manual


 
Instruction Manual
IB-106-340 Rev. 3.0
December 2003
2-14 Installation Rosemount Analytical Inc. A Division of Emerson Process Management
Oxymitter 4000
TYPE K
THERMOCOUPLE
SIGNAL
HEATER POWER
(BELOW COVER)
OXYGEN
SIGNAL
+
+
-
-
LINE 1
NEUTRAL
GROUND
90-250 VAC, 50-60 HZ
LINE VOLTAGE INPUT
TERMINAL
BLOCK
GROUND
LUGS
37260053
LINE VOLTAGE
4-20 mA
SIGNAL
AC L1
AC N
+
+
-
-
4-20
TERMINAL
BLOCK
GROUND LUGS
BLU
ORN
RED
YEL
BLK
WHT
4-20 mA +
4-20 mA
GROUND
LINE 1
NEUTRAL
GROUND
90-250 VAC, 50-60 HZ
LINE VOLTAGE INPUT
CALIBRATION
HANDSHAKE/
LOGIC I/O
PROBE
REMOTE
ELECTRONICS
1234 56
GRN
ORN
YEL
RED
BLK
BLK
BLU
ORN
YEL
RED
WHT
BLK
HTR
T/C
O
CELL
2
(BY FACTORY)
TO ELECTRONICS
FROM PROBE
CALIBRATION HANDSHAKE
WALL-MOUNTED
SPS 4000
INTERCONNECTING
CABLE
Figure 2-10. Electrical Installation – Oxymitter 4000 with Remote Electronics (Sheet 2 of 2)