Rosemount Analytical Inc. A Division of Emerson Process Management Description and Specifications 1-17
Oxymitter 4000
Table 1-1. Product Matrix (Continued)
Cont’d Code Communications
1 HART with Membrane Keypad, blind cover
2 HART with Membrane Keypad, glass cover
3 HART with Local Operator Interface, glass cover, English only
Code Language
1 English
2German
3 French
4 Spanish
5 Italian
Code Filtered Customer Termination
00 Specified as Part of Electronics Housing
Code Calibration Accessories
00 No Hardware
01 Calibration Gas Flowmeter and Reference Air Set
02 Intelligent Multiprobe Sequencer (Refer to Table 1-3)
03 Single Probe Sequencer, Horizontal Orientation, Brass/Teflon, no Reference Air Set
04 Single Probe Sequencer, Horizontal Orientation, Brass/Teflon, with Reference Air Set
05 Single Probe Sequencer, Horizontal Orientation, Stainless Steel, no Reference Air Set
06 Single Probe Sequencer, Horizontal Orientation, Stainless Steel, with Reference Air Set
07 Single Probe Sequencer, Vertical Orientation, Brass/Teflon, no Reference Air Set
08 Single Probe Sequencer, Vertical Orientation, Brass/Teflon, with Reference Air Set
09 Single Probe Sequencer, Vertical Orientation, Stainless Steel, no Reference Air Set
10 Single Probe Sequencer, Vertical Orientation, Stainless Steel, with Reference Air Set
Code Electronics to Probe Cable Length
00 No Cable
10 20 ft (6 m) Cable
11 40 ft (12 m) Cable
12 60 ft (18 m) Cable
13 80 ft (24 m) Cable
14 100 ft (30 m) Cable
15 150 ft (45 m) Cable
16 200 ft (61 m) Cable
Cont’d 2 2 00 09
14
Example
NOTES:
(1)
Recommended usages: High velocity particulates in flue stream, installation within 11.5 ft (3.5 m) of soot blowers or heavy salt cake buildup.
Applications: Pulverized coal, recovery boilers, lime kiln. Regardless of application, abrasive shields with support brackets are recommended
for 9 ft (2.74 m), 12 ft (3.66 m), 15 ft (4.57 m), and 18 ft (5.49 m) probe installations, particularly horizontal installations.
(2)
Where possible, specify SPS number; otherwise, provide details of the existing mounting plate as follows:
Plate with studs Bolt circle diameter, number, and arrangement of studs, stud thread, stud height above mounting plate.
Plate without studs Bolt circle diameter, number, and arrangement of holes, thread, depth of stud mounting plate with accessories.
Table 1-2. Calibration Components
Part Number Description
1A99119G01 Two disposable gas bottles — 0.4% and 8% O
2
, balance nitrogen — 550 liters each*
1A99119G02 Two flow regulators for calibration gas bottles
1A99119G03 Bottle rack
* Calibration gas bottles cannot be shipped via airfreight. When bottles are used with “CALIBRATION RECOMMENDED” features,
the bottles should provide 2 to 3 years of calibrations in normal service.