Emerson Process Management 8732 Oxygen Equipment User Manual


 
Reference Manual
00809-0100-4663, Rev BA
January 2010
B-5
Rosemount 8732
HAZARDOUS LOCATION
CERTIFICATIONS
Equivalent Hazardous Location Certifications for sensor and transmitter must
match in integrally-mounted magnetic flowmeter systems. Remote-mounted
systems do not require matched hazardous location certification option codes.
Transmitter Approval
Information
Table B-5. Transmitter Option
Codes
Equipment Category 1 - Dust Environment
Dust Environment Only
Trans: Dust Ignition Proof NF - NF
Other Certifications Product Certification Code
(3)
European Pressure Equipment
Directive (PED)
PD - PD
NSF 61 Drinking Water
(4)
DW - DW
(1) Available in remote mount configuration only. Requires equivalent ATEX approval on the sensor
(2) For I.S. Output, Output Code B must be ordered
(3) Product Certification Codes are added to the Sensor model number only
(4) Only available with PTFE (all line sizes) or Polyurethane (4 in. or larger) Lining Materials and
316L SST Electrodes
Rosemount
8732E
Rosemount
8712D
Rosemount
8712H
Approval Codes HART
FOUNDATION
fieldbus
NA
N0
N1
N5
N7
ND
NF
E1
E5
E7
ED