Emerson Process Management 8732 Oxygen Equipment User Manual


 
Reference Manual
00809-0100-4663, Rev BA
January 2010
H-7
Rosemount 8732
OFF KEY DISABLED Appears when the user attempts to turn the HC off before sending
modified data or before completing a method
On-line device disconnected with unsent data – RETRY or OK to
lose data
There is unsent data for a previously connected device. Press RETRY
to send data, or press OK to disconnect and lose unsent data.
Out of memory for hot key configuration – delete unnecessary
items
There is no more memory available to store additional hot key items.
Unnecessary items should be deleted to make space available.
Overwrite existing configuration memory Requests permission to overwrite existing configuration either by a
device-to-memory transfer or by an off-line configuration; user answers
using the softkeys
Press OK... Press the OK softkey – this message usually appears after an error
message from the application or as a result of hart communications.
Restore device value? The edited value that was sent to a device was not properly
implemented. Restoring the device value returns the variable to its
original value.
Save data from device to configuration memory Prompts user to press SAVE softkey to initiate a device-to-memory
transfer
Saving data to configuration memory Data is being transferred from a device to configuration memory.
Sending data to device Data is being transferred from configuration memory to a device.
There are write only variables which have not been edited.
Please edit them.
There are write-only variables which have not been set by the user.
These variables should be set or invalid values may be sent to the
device.
There is unsent data. Send it before shutting off? Press YES to send unsent data and turn the HC off. Press NO to turn
the HC off and lose the unsent data.
Too few data bytes received Command returns fewer data bytes than expected as determined by the
device description
Transmitter Fault Device returns a command response indicating a fault with the
connected device
Units for <variable label> has changed – unit must be sent before
editing, or invalid data will be sent
The engineering units for this variable have been edited. Send
engineering units to the device before editing this variable.
Unsent data to on-line device – SEND or LOSE data There is unsent data for a previously connected device which must be
sent or thrown away before connecting to another device.
Use up/down arrows to change contrast. Press DONE when done. Gives direction to change the contrast of the HC display
Value out of range The user-entered value is either not within the range for the given type
and size of variable or not within the min/max specified by the device.
<message> occurred reading/writing <variable label> Either a read/write command indicates too few data bytes received,
transmitter fault, invalid response code, invalid response command,
invalid reply data field, or failed pre- or post-read method; or a response
code of any class other than SUCCESS is returned reading a particular
variable.
<variable label> has an unknown value – unit must be sent before
editing, or invalid data will be sent
A variable related to this variable has been edited. Send related variable
to the device before editing this variable.
Table H-1. Handheld Communicator Diagnostic Messages
Message Description