3. READING / WRITING DATA
25
BAS-311G, BAS-326G
3-4. Data read/write mode
1
With the power turned off, insert the CF card into the CF
slot.
NOTE:
Make sure the CF card is facing the correct way.
Always be sure to keep the cover closed except
when inserting and removing the CF card. If this is
not done, dust may get inside and cause problems
with operation.
If no valid data can be found, the CF media indicator
will not illuminate.
2
Turn on the power switch.
3
Switch to data read/write mode.
TEST indicator and CF media indicator illuminate
While pressing the TEST key, press the R/W key.
The mode number will appear in the PROGRAM No.
display, and the setting details for that mode will
appear in the menu display.
The initial mode is sewing data reading mode. (Refer
to the read/write mode list)
4
Press the or key to select the mode.
[Read/write mode list]
PROGRAM No.
display
Menu display Setting items
r 1 [-SEd] Sewing data is read from the CF card. (*1)
w 2 [SEd-] Sewing data is written to the CF card.
r 3 [-MEM] Memory switch settings are read from the CF card.
w 4 [MEM-] Memory switch settings are written to the CF card.
r 5 [-UPG] User programs are read from the CF card.
w 6 [UPG-] User programs are written to the CF card.
r 7 [-SyS] Control programs are read from the CF card and used to update the firmware version.
w 8 [LoG-] Error log data is written to the CF card.
r 9 [-Fdd] Sewing data is read from the floppy disk. (*2) (*3)
w 10 [Fdd-] Sewing data is written to the floppy disk. (*2)
r 11 [-EoP] Extended option output (*4) data is read from the CF card.
w 12 [EoP-] Extended option output data is written to the CF card.
r 13 [oPFd] Extended option output data is read from the floppy disk. (*2)
*1 The sewing data that can be use with this sewing machine is data that has been created for the BAS-311G/BAS-326G.
*2 Only valid when using an optional floppy disk drive.
*3 Sewing data for the BAS-300 series, BAS-300A series and BAS-300E/F series can be read.
*4 Refer to the instruction manual for the programmer for details on extended option output.
4453Q
4574Q
4575Q