Problem #1 The power indicator does not illuminate when the power is turned on.
Cause Inspection/Remedy/Adjustment Replacement if a malfunction
1. Malfunction of voltage select
harness ***
For 200 V specifications
a. Check if there is a broken wire in the voltage
select harness.
b. Disconnect the connector at the transformer
side, turn on the power and then measure the
voltage at the cord.
(The wiring position may vary depending on
the voltage specifications.)
OK if same as wall outlet voltage
Voltage select harness ***
(*** indicates voltage
specifications)
2. Malfunction of transformer
100V, 200V, 220 V specifications
380V, 400V specifications
For 100V, 200V, 220 V specifications
1) OK if there is continuity between pins
1-8, 2-8, 3-8, 4-8, 5-8 and 6-8 of the
8-pin connector coming out from the
transformer. [Fig. A]
2) OK if there is continuity between pins
1-2, 3-4 and 5-6 of the 6-pin connector
coming out from the transformer.
[Fig. C]
3) OK if there is continuity between pins
1-2 and 4-5 of the 5-pin connector
coming out from the transformer.
[Fig. D]
For 380V, 400V specifications
1) OK if there is continuity between pins
1-3, 2-3 and 3-6 of the 6-pin connector
coming out from the transformer.
[Fig. B]
2) OK if there is continuity between pins
1-2, 3-4 and 5-6 of the 6-pin connector
coming out from the transformer.
[Fig. C]
3) OK if there is continuity between pins
1-2 and 4-5 of the 5-pin connector
coming out from the transformer.
[Fig. D]
Transformer
Voltage
specifications
Pin No.
100V 6-8
110V 5-8
120V 4-8
200V 3-8
220V 2-8
240V 2-7
H220V 3-6
380V 2-3
400V 1-3
4876Q
4879Q
4877Q
4878Q