Brother BAS-311G Wheelchair User Manual


 
2. FUNCTION SETTINGS
8
BAS-311G, BAS-326G
Sewing machine motor settings
No.
Setting
range
Setting items Initial value
Highest needle position stop
OFF Disabled
150
ON
When the upper shaft stops, the motor operates in reverse to return the needle bar
close to its highest position.
(When the motor operates in reverse to raise the needle, the thread take-up will
stop at a position which is lower than its normal stopping position. As a result, the
thread take-up will rise slightly at the sewing start, and this may result in the thread
pulling out under certain conditions.)
OFF
1st stitch sewing speed at the sewing start
151
4 27
(Units x100 rpm)
4
2nd stitch sewing speed at the sewing start
152
4 27
(Units x100 rpm)
8
3rd stitch sewing speed at the sewing start
153
4 27
(Units x100 rpm)
12
4th stitch sewing speed at the sewing start
154
4 27
(Units x100 rpm)
27
5th stitch sewing speed at the sewing start
155
4 27
(Units x100 rpm)
27
5th last stitch sewing speed at the sewing end
156
4 27
(Units x100 rpm)
27
4th last stitch sewing speed at the sewing end
157
4 27
(Units x100 rpm)
27
3rd last stitch sewing speed at the sewing end
158
4 27
(Units x100 rpm)
27
2nd last stitch sewing speed at the sewing end
159
4 20
(Units x100 rpm)
12
Piercing force boosting operation
OFF Disabled
161
ON
Piercing force boosting operations are carried out when the sewing machine motor
is locked
OFF
Regulation of sewing speed changes due to sewing pitch changes
OFF Sewing speed varies depending on sewing pitch of the sewing data
162
ON
Speed is fixed at the minimum sewing speed for the maximum pitch of the sewing
data
(Set to ON if there may be a problem with sewing speed changes as a result of
pitch changes.)
OFF
Limits the maximum sewing speed.
163
12 27
(Units x100 rpm)
27
Thread trimming disabled
OFF Thread trimming is carried out in accordance with the sewing data.
164
ON All thread trimming operations are disabled.
OFF
Highest needle position stop angle (Units 2 degree steps) (*4)
165
-15 0
0: Normal needle up position: Needle bar height increases for values in the
negative direction.
0
*4 If the setting value becomes to large in the negative direction, error “E110” may be generated at the first sewing start
after the power is turned on.