Brother BAS-311G Wheelchair User Manual


 
2. FUNCTION SETTINGS
18
BAS-311G, BAS-326G
PROGRAM No. display Menu display
Check code Name Input status
Check item and checking method
[ 8] [ UP] [ on] / [ oFF]
Needle up signal
Turn the pulley by hand.
[ 9] [ dn] [ on] / [ oFF]
Needle drop signal
Turn the pulley by hand.
[ 10] [voL]
[ 0] [ 300]
Power supply voltage
Displayed as %
[ 11] [PnL] [*] / [ oFF]
Operation panel input check
While a key is being pressed, the name of the key will be
displayed.
*ON display Key name
[rESt] RESET key
[tESt] TEST key
[tHrE] THREAD/CLAMP key
[ tEn] TENSION/WIND key
[SELE] SELECT key
[UP-M] key
[dn-M] key
[ F1] Function key F1
[ F2] Function key F2
[ F3] Function key F3
[ F4] Function key F4
[ CF] R/W key
[ 12] [FtA]
[ 0] [ 255]
Foot switch analog value (Single pedal specifications)
Depress the foot switch.
[ 13] [CL1] [ on] / [ oFF]
Work clamp 1st step (2 pedal specifications)
Depress the foot switch to the 1st step.
[ 14] [CL2] [ on] / [ oFF]
Work clamp 2nd step (2 pedal specifications)
Depress the foot switch to the 2nd step.
[ 15] [Stt] [ on] / [ oFF]
Start switch (2 pedal specifications)
Depress the foot switch to the 2nd step.
[ 16] [EMC]
[ on]
[on ]
[ ]
STOP switch
Press the STOP switch.
[ 17] [HEd] [ on] / [ oFF]
Machine head switch
Tilt back the machine head.
[ 18] [EXE] [ on] / [ oFF] External input error detection (IN13)
[ 19] [CAH] [ on] / [ oFF]
Thread nipper hope position sensor (IN14) (*1)
Press the
key to move the thread nipper in the home position
direction.
Press the
key to move the thread nipper in the retract
direction.
[ 20] [rEL] [ on] / [ oFF]
Thread nipper retract sensor (IN15) (*1)
Press the key to move the thread nipper in the home position
direction.
Press the
key to move the thread nipper in the retract
direction.
[ 21] [in1] [ on] / [ oFF] Option input (IN1)
[ 22] [in2] [ on] / [ oFF] Option input (IN2)
[ 23] [in3] [ on] / [ oFF] Option input (IN3)
[ 24] [in4] [ on] / [ oFF] Option input (IN4)
[ 25] [in5] [ on] / [ oFF] Option input (IN5)
[ 26] [rot] [ on] / [ oFF] Option input (IN11)
[ 27] [Fib] [ on] / [ oFF] Fiber-type thread breakage detection [Option compatibility]
*1 Not used for the BAS-311G and BAS-326G.