Brother BAS-311G Wheelchair User Manual


 
2. FUNCTION SETTINGS
5
BAS-311G, BAS-326G
2-4. List of memory switch settings
No.
Setting
range
Setting items Initial value
Work clamp lift timing after sewing is completed
OFF Lifts at the final stitch position.
001
ON Lifts after moving to the home position.
ON
Separate-type work clamp drop operation (pneumatic specifications)
0 Left and right work clamp drop at the same time.
1
Work clamp drops in the order left right.
002
2
Work clamp drops in the order right left.
0
Work clamp drop operation (solenoid specifications)
0
Analog dropping: Work clamp drops in direct proportion to the pedal depression
amount, and sewing starts when the pedal is fully depressed
1
1st step drop: Work clamp drops when pedal is depressed to the 1st step, and
sewing starts when pedal is depressed to the 2nd step
003
2
2nd step drop: Work clamp drops to intermediate height when the pedal is
depressed to the 1st step, and work clamp drops and sewing starts when the
pedal is depressed to the 2nd step.
2
Sewing start speed
OFF
The sewing speed for the first 1 5 stitches is set by memory switch numbers 151
155.
100
ON
1st stitch at 400 rpm, 2nd stitch at 400 rpm, 3rd stitch at 600 rpm, 4th stitch at 900
rpm, 5th stitch at 2,000 rpm
OFF
Single-stitch test feed
OFF
Test feed starts when the foot switch (start switch) is depressed, and it continues
automatically until the final stitch.
200
ON
Test feed is carried out one stitch at a time when the foot switch (start switch) is
depressed (feed becomes continuous if the foot switch [start switch] is
continuously depressed).
In addition, when the TEST indicator is illuminated, test feeding will move forward
one stitch at a time when the machine pulley is turned by hand.
OFF
Production counter display
OFF Lower thread counter display
300
ON Production counter display
OFF
User programs
OFF Disabled
400
ON User program mode is enabled.
OFF
Cycle programs
OFF Disabled
401
ON When sewing user programs, the set programs are sewn in numeric order.
OFF
Maximum reduction ratio (mm display) (*1)
OFF Displayed as %.
402
ON Displayed as mm.
OFF
Split mode selection
0 Continuous split (split menu is disabled before split detection)
1 Continuous split (split menu is always enabled)
403
2 Independent split
0
*1 The mm display may differ slightly from the actual sewing size.