Brother BAS-311G Wheelchair User Manual


 
9. TABLE OF ERROR CODES
BAS-311G, BAS-326G
137
9. TABLE OF ERROR CODES
DANGER
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet
before opening the cover of the control box. Touching areas where high voltages are present can result in severe
injury.
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display
window. Follow the remedy procedure to eliminate the cause of the problem.
Switch-related errors
Code
Cause and remedy
E010
Stop switch was pressed. Press the RESET key to clear the error.
E011
Stop switch was pressed. Press the RESET key to clear the error.
Press the
key to move the feed mechanism so that you can continue sewing.
E015
The stop switch was still being pressed, or there is a problem with the stop switch connection.
Turn off the power, and then check that connector P13 on the main P.C. board is properly connected.
E016
Problem with the stop switch connection.
Turn off the power, and then check that connector P13 on the main P.C. board is properly connected.
E025
Foot switch is depressed to the 2nd step. (If using a two-pedal foot switch, the power was turned on while the
start switch was still depressed, or the start switch was pressed without the work clamp being lowered.)
Turn off the power and check the foot switch.
E035
Foot switch is depressed to the 1st step. (Work clamp switch if using a two-pedal foot switch)
Turn off the power and check the foot switch.
E036
Work clamp motions are not set correctly.
Set memory switch No. 050 or 003 correctly in accordance with the type of foot switch being used.
E050
Machine head tilting was detected after the power was turned on.
Turn off the power, and then return the machine head to its original position.
Check that connector P9 on the main P.C. board is properly connected.
E051
Machine head tilting was detected while the sewing machine was operating.
Turn off the power, and then check that connector P9 on the main P.C. board is properly connected.
E055
Machine head tilting was detected when the power was turned on.
Turn off the power, and then return the machine head to its original position.
Check that connector P9 on the main P.C. board is properly connected.
E065
An operation panel key was still being pressed when the power was turned on, or key is faulty.
Turn off the power and check the operation panel.