Brother BAS-311G Wheelchair User Manual


 
2. FUNCTION SETTINGS
12
BAS-311G, BAS-326G
No.
Setting
range
Setting items Initial value
Thread breakage detector
OFF Disabled
554
ON Fiber-type thread breakage detector used
OFF
Thread breakage detector detection sensitivity
OFF 5 stitches at sewing start, 3 stitches while sewing
555
ON 10 stitches at sewing start, 3 stitches while sewing
OFF
Inner clamping device (Option output No. 13)
0 Disabled
1
Inner clamping device is used.
(Retract operation is carried out at the sewing end to prevent interference with the
needle.)
2 Inner clamping device is used. (No retract operation at the sewing end.)
556
3
Inner clamping device operates for 1/4 of the sewing pattern and returns for the
other 3/4.
(No retract operation)
0
External wiper device
0 Disabled
1 Solenoid-type wiper device is used.
557
2 Pneumatic-type wiper device is used. (Option output No. 2)
1
External error monitoring input
OFF Disabled
558
ON Enabled (P10, option input No. 13 [AIRSW])
OFF
Operating indicator output
OFF Disabled
559
ON
Option output No. 9: Output ON while operating
Option output No. 10: ON during lower thread conversion and during test mode
Option output No. 11: ON when error is generated
OFF
Automatic ejector (Option output No. 3 output, option input No. 1 = right sensor, input No. 2 = left
sensor) [Pneumatic specifications]
0 Disabled
1 Standard operation
2 Sewing starts when cassette sensor is ON
560
3 Start switch is enabled even if cassette sensor is OFF.
0
Timer from sensor detection to sewing start when automatic ejector automatic starting is set
(memory switch No. 560 = 2) [Pneumatic specifications]
561
0 999
Time from after the cassette is chucked until automatic starting
100
Changes the digital tension setting value.
OFF Tension number can be changed regardless of the sewing data.
562
ON
Only tension No. 0 and the tension numbers detected in the sewing data can be
changed.
ON
2-step tension is possible (When using spring-type main tension)
OFF Disabled
563
ON 2-step tension is used.
OFF
Increases maximum tension release force when using a spring-type main tension
0 Disabled (Tension release is open at the sewing end.)
1
Increases the force (Tension release is closed at the sewing end. If tension release
is open, it will be closed in approximately 5 minutes.)
564
2
Increases force to the maximum. (Tension release is closed at the sewing end. If
tension release is open, it will be closed in approximately 1 minute.)
0
Thread nipper device (*6)
OFF Disabled
565
ON
Thread nipper device installed (Memory switch No. 500 must also be set to ON or
OFF.)
OFF
*6 Not used for the BAS-311G and BAS-326G.