Probescanbemountedatanyangle.However,iftheprobeistobemountedonaverticalductwall,it
isbettertoangletheprobe(approx.15°)downtoavoidprocesscondensationinsidethecoldendof
theprobe.Ifthereareanyparticulatesinthefluegas,afiltercanbeomittedbypointingtheprobe
verticallydownwards.Otherwisethetransmittercanbeconfiguredtoautomaticallypurgethefilters
,
ortheycanbereplaced
periodically.
OxygenProbeMounting


CAUTION
Itisimportantthatthereisnoairinleakageupstreamoftheoxygensensingpointotherwise
therewillbeahighoxygenreading.
Iftheprobeistobeinstalledonabendintheflue,itisbestlocatedontheoutercircumference
ofthebendtoavoiddeadpocketsoffluegasflow.Whilethestandard9060pr
obewitha‘U’
lengthof250 mm(10”)willsuit mostlowtemperatureflueapplications,it isoccasionally
necessarytohavealongerprobewiththesensingtipinthecentreofthefluegasstream.
Althoughitisrare,occasionallyaprobemaysenseoxygenvastlydifferentlyfromtheaverage
reading in the flue gas. If it occurs, then the probe should be moved, or a longer probe
installed.Thisphenomenonisnormallycausedbystratificationofthefluegas.