14. PROGRAMMING MODE
EO1-31009
14.2 PLU Data Setting
14- 7
Item Procedure
Tare,
%Tare
Input a numeric data (max. 2lb for lb scale, 1kg for kg scale, or 99.9%
for %Tare).
NOTES:
1. With the initial settings, Preset tare and %Tare function is not available.
When these functions are required, contact the nearest TOSHIBA TEC
service representative or sales agent.
2. %Tare data exceeding the tare limit results in an error.
3. When the NET statement labels are to be issued, enter the net weight (0 –
480 oz) to the PLU tare area.
Tare Limit 1. Input a numeric data in the following range:
Lb scale: 0.000 – 2.000lb (Default: 2.000lb)
Kg scale: 0.000kg – 1.000kg (Default: 1.000kg)
2. Touch the Tare Limit area.
3. The confirmation screen will appear.
4. Touch the [Go] key to enter the data. To cancel, touch the [Cancel]
key.
NOTES:
1. With the initial settings, this function is not available. When this function is
required, contact the nearest TOSHIBA TEC service representative or sales
agent.
2. If the actual tare exceeds the tare limit, an error occurs.
Compulsory tare
subtraction
Select YES or NO.
YES: Tare subtraction is compulsory.
NO: Tare subtraction is not compulsory.
NOTE: With the initial settings, YES cannot be selected. When this function
is required, contact the nearest TOSHIBA TEC service representative or