9.3.2 Holding (Pausing) Recipe Execution
To hold execution of a CN8-SW recipe:
1. While logged in as MULTI (or another user with View/Change Parameter privileges),
select Ramp/Soak | Hold. The Recipe Control window will open.
2. The window lists all the recipes being run under the direction of CN8-SW.
A recipe may appear on the list in the left pane more than once. This means that you
started to run the recipe on different controllers (or sets of controllers) at different
times. Each of these occurrences of a recipe on the list is referred to as an
ÒinstanceÓ of the recipe.
To see on which controller(s) you are currently executing an instance of a recipe,
click on the name of the recipe. The controllers running the selected instance of the
recipe that are not already on hold will be listed in the right pane.
14
3. Select the instance of the recipe to be held.
4. Select the controllers to be held. (You can hold down the Shift key to select multiple
controllers that are together on the list, or hold down the Control key to select multiple
controllers that are scattered on the list.)
5. Click on Hold. Execution of the selected instance of the CN8-SW recipe will be
paused for the selected controllers, and the window will close. On the CN8-SW main
display, the PV of the ÒheldÓ controllers will alternate with the display of ÒHOLdÓ.
Execution of the selected instance of the recipe will be held for the selected controllers
until you resume execution as described in 9.3.3, or stop (terminate) execution as
described in 9.3.4.
14
If all controllers on which you are running the selected recipe instance are already held, then no
controllers will be listed in the right pane.