Figure 35. Correct Reflector Alignment (I310M/I311M)
7. Align the reflector squarely over the opening. With gentle pressure and a rocking
motion, slide the reflector down in place. It should not bind against the end
reflectors as it goes into place. As a final motion, grasp the sides of the reflector
and gently force them together a small amount, then settle the reflector down
over the mounting surfaces (Figure 33). Start the six flat head screws in the
reflector but do not tighten. Tighten the six screws in the sequence 1-6 as shown
in Figure 36 to a snug position; finally tighten to 3.4 N-m (30 inch-lbs.) using a
torque-controlled screwdriver. Repeat tightening the screws according to the
illustrated sequence, and at the specified torque.