Electrical inputs to the lamp module are provided by a high voltage/control cable with
a quick-connect fitting which supplies power for the magnetron, filament transformer
and the interlock circuitry.
System Components
The basic F300S/F300SQ system consists of the following items:
A P300M/P300MQ/P300MT power supply
An HV Cable H340 (no modular blower)
An HV Cable H341 (with modular blower)
An I300 series irradiator
An RF detector cable H790
An RF-1 detector
In addition, the user must supply the following if not provided by Fusion UV Systems:
Cooling for the irradiator, if no modular blower is provided. (See Appendix A,
“Specifications” and Appendix C, “Outline Drawings” for irradiator cooling
requirements.)
Mechanical mounting of the lamp modules over a substrate, conveyor, or other
transport mechanism
Light shield surrounding the lamps
Exhaust system for the light shield
Any desired interlock mechanisms (see Chapter 3 on page 39)
Electrical wiring of the power supply into the plant electrical system
Control
The control system of the F300S/F300SQ provides precise control of high voltage and
filament voltage supplies. The control board also monitors cooling air pressure,
detection of RF, power levels, bulb ignition, and interlocks such as transformer
thermal switches. If a problem arises, the control system turns off all high voltage
power to the lamp and flashes a fault LED indicator on the power supply control panel.
Inputs for customer ON/OFF control are available. Outputs allow detection of
STANDBY or LAMP ON operation, or of interlock failures.