High Voltage
Insulated electrical cables carry power at 3900 Volts from the power supply to the
lamp. These voltages can be dangerous, so some precautions should be taken in both
the location and protection of these lines. High voltages are exposed within the power
supply chassis, which should never be operated without its cover.
A high quality cable, rated at 10,000 Volts, is used in all high voltage cables
manufactured by Fusion UV Systems, and can be supplied to users for any additional
connections that may be required.
UV Curable Materials
Please consult your UV materials supplier for recommended precautions regarding the
proper handling and use of these products.
DANGER: Never touch the power supply/lamp cable
connections while the system is ON or in STANDBY. A faulty
magnetron may cause 7000 Volts DC to appear on connector
pins and may cause serious injury.
Do not touch power supply/irradiator harness plug P10 near the
contacts, and do not lay P10 down on any conductive material.
Never troubleshoot the power supply without first disconnecting
all external power and discharging the high voltage capacitors
with an insulated screwdriver.