Connecting PelcoNet To a CM6800 and KBD200 For Remote
ASCII Control
Refer to Figure 54. This configuration lets an operator view and control cameras with a remote KBD200
keyboard. All settings are done in the CM6800 manager program or through a CM6800 menu. Note the
following:
Port 2 defaults to ASCII and RS-232.
Ports 7 and 8 can be set to ASCII and RS-232 by using the CM6800 manager program (refer to
Figure 52) or by using a CM6800 menu (refer to Figure 53).
Pelco recommends using Port 2.
Figure 54. Using PelcoNet with CM6800 and KBD200 to Provide Remote Control
PV130
TD(A)
TD(B)
RD(A)
RD(B)
GND
+12 VDC
PELCONET REMOTE KBD200 ASCII MODE SETUP
1
2
3
4
8
7
6
5
GND
12V
TRANSPARENT DATA PORT
KBD200
TO NETWORK (LAN / WAN)
RD(A)
RD(B)
TD(B)
TD(A)
12VAC
RJ-45 WALL BLOCK AND
STRAIGHT CABLE SUPPLIED
TRANSPARENT DATA PORT
CONTROL
TERMINAL
ALARM I/O
2-RX
3-TX
5-GND
VIDEO OUT
PELCONET
RECEIVER
USING INTERNET EXPLORER,
SET TRANSPARENT DATA SETTINGS
ON BOTH PELCONET RECEIVER AND
TRANSMITTER:
BAUD RATE 9600
DATA BITS 8
PARITY ODD
STOP BIT 1
TO NETWORK (LAN / WAN)
CONTROL
TERMINAL
ALARM I/O
PELCONET
TRANSMITTER
SPECTRA COAXITRON
®
PROTOCOL
VIDEO IN
2-RX
3-TX
5-GND
0
C
A
M
NOTE: FIRMWARE VER. 4.0 OR LATER REQUIRED.
SET KEYBOARD DIP SWITCHES - SWITCH
6 ON, SWITCHES 5 AND 8 OFF, SWITCHES
1-4 FOR ADDRESS ACCORDING TO THE
TABLE IN THE KBD200 MANUAL.
PV130 ORDERED SEPARATELY
PELCONET CM6800-48X8
TRANSPARENT DATA PORT COM2
2 RXD...................................................8 TXD
3 TXD................................................... 1 RXD
5 GND.................................................. 5 GND
CONNECT PELCONET TO 6800 VIA RS-232 PORT
6800 MATRIX COM 2
PORT SETTINGS:
BAUD RATE 9600
DATA BITS 8
PARITY ODD
STOP BIT 1
CM6800-48X8
00668