Pelco C1977M-D Pacemaker User Manual


 
Pelco Manual C1977M-D (6/02) [ 85 ]
Connecting a Pelconet Transmitter To The CM6800 ASCII Port
Refer to Figure 51. This configuration lets an operator view and control cameras with a PC using a web
browser. (The operator’s PC is not shown on the diagram.) All settings are done in the CM6800 manager
program or through a CM6800 menu. Note the following:
Port 2 defaults to ASCII and RS-232.
Ports 7 and 8 can be set to ASCII and RS-232 by using the CM6800 manager program (refer to
Figure 51) or by using a CM6800 menu (refer to Figure 52).
Pelco recommends using Port 2.
TRANSPARENT DATA PORT
TO NETWORK (LAN / WAN)
CONTROL
TERMINAL
ALARM I/O
PELCONET
TRANSMITTER
SPECTRA COAXITRON
®
PROTOCOL
VIDEO IN
2-RX
3-TX
5-GND
PELCONET CM6800-48X8
TRANSPARENT DATA PORT COM2
2 RXD...................................................8 TXD
3 TXD................................................... 1 RXD
5 GND.................................................. 5 GND
CONNECT PELCONET TO 6800 VIA RS-232 PORT
6800 MATRIX COM 2
PORT SETTINGS:
BAUD RATE 9600
DATA BITS 8
PARITY ODD
STOP BIT 1
USING INTERNET EXPLORER,
SET TRANSPARENT DATA
PORT SETTINGS:
BAUD RATE 9600
DATA BITS 8
PARITY ODD
STOP BIT 1
CM6800-48X8
PELCONET CM6800 ASCII PORT SETUP
00669
Figure 51. Using PelcoNet with CM6800 to Provide Remote Control