Pelco C1977M-D Pacemaker User Manual


 
Pelco Manual C1977M-D (6/02) [ 73 ]
1. Connect a PV130 Converter to the RS-232 port on the front of the PelcoNet Transmission System
receiver. The data format should be 9600 baud, 8 data bits, odd parity, and 1 stop bit.
2. Connect the black and white striped wire from the power supply that came with the converter to the
converter’s +12 VDC terminal and the solid black wire to the GND terminal.
3. Connect TD(A) on the converter to terminal 7 on the wall block. Connect TD(B) on the converter to
terminal 8 on the wall block. Connect RD(A) on the converter to terminal 2 on the wall block. Connect
RD(B) on the converter to terminal 1 on the wall block.
4. Connect the 12 VAC power supply to terminals 3 and 4 on the wall block.
5. Connect the wall block to the KBD4000 with an RJ-45 straight cable.
6. Connect the monitor.
7. Repeat steps 1 and 2 for the transmitter.
8. Connect TD(A) on the converter to terminal 2 on the wall block. Connect TD(B) on the converter to
terminal 1 on the wall block. Connect RD(A) on the converter to terminal 7 on the wall block. Connect
RD(B) on the converter to terminal 8 on the wall block.
9. Connect the wall block to COM IN on the multiplexer with an RJ-45 straight cable.
10. Connect MAIN video output from the multiplexer to the transmitter.