Furuno BR-500 Medical Alarms User Manual


 
4. INSTALLATION
4-13
4.7.2 Wiring information
Item Description
Operator fitness FAR-2105: It is not possible to create a connection for operator fitness
between FAR-2105 and the Processor Unit, because the FAR-2105
does not have operator fitness output.
FAR-2107: Use port J612 (pin #7/8 for operator fitness), where a con-
tact signal is available.
Other makes of radars: Check for availability of contact signal.
FRU12-05AFFM
(between BR-510 and
BR-520)
This cable is fit with a Micro-C connector (male) on one end and a stripped
end for connection to the BR-520. The standard length is 6 m. 10 m, 20 m,
30 m, 40 m, and 50 m cables are optionally available.
Cable MPYC-7
(between BR-530/550
and BR-520)
40 m and the total length for all units is max. 150 m. For example, when
four BR-530 are installed: No.1 BR-530: 40 m No. 2 BR-530: 40 m No. 3
BR-530: 40 m No. 4 BR-530: 30 m Total length: 150 m
Motion Detector
BR-560
• Pyroelectric detection
Detection range: Up to 5m, 80°×80°
Detection rate: 0.8 thru 1.2 m/s
• Detection sensitivity: 4°C (difference from surround in temperature)
Generally, up to two Motion Detectors can be installed, at INPUT3/4 and
INPUT5-8. Also, INPUT port 2 can be used by setting [INPUT2] on the Ser-
vice menu to [Timer Reset].
506
10 10
Connect cores
to WAGO terminal block.
Vinyl tape
Set this part
in cable clamp.
SIgnal cable FRU12-05AFFM (Main Alarm Panel)
80 mm 80 mm
Fix cables to post with cable tie
Wrap wires with
vinyl tape.
Wrap armor with
vinyl tape.
How to fabricate cables for processor unit