4. INSTALLATION
4-2
4.2 Mounting Considerations
Do the installation following the information in IEC 62616 Annex A and IMO
MSC.128(75).
Locate the units away from exhaust pipes and vents.
Make sure the location has good ventilation.
Mount the units where shock and vibration are minimal.
Locate the units away from the equipment that generates electromagnetic fields,
such as a motor or generator.
Follow the maintenance space indicated in the outline drawings, to facilitate main-
tenance and servicing.
Follow the compass safe distances indicated on page iii to prevent interference to
a magnetic compass.
Keep the units away from direct sunlight to prevent heat that can build up inside their
cabinets. The LCD of the Main Alarm Panel BR-510 can darken if put in direct sun-
light.
For the Main Alarm Panel, the optimal viewing distance is 0.5 m. Select a location
within that distance.
For the Main Alarm Panel, Timer Reset Panel, Motion Detector:
Locate the units on the bridge where a proper lookout is available.
The means of activating the reset functions shall be easily accessible from the
conning position, the workstation for navigating and maneuvering, and the work-
station for monitoring and the bridge wings (if applicable).
The 1st stage audible alarm shall be audible from all operational positions on the
bridge where the OOW may reasonably be expected to be stationed.
On the Motion Detector installation, obstructions must not be within the detect-
ing range of the sensor. Observe the requirements shown in the illustration when
you select an installation location.
For the Flash Beacon, the flashing indication shall be visible from all operational
positions on the bridge where the OOW may reasonably be expected to be sta-
tioned.
MOTION
DETECTOR
2m
1.6m