Furuno BR-500 Medical Alarms User Manual


 
1. MAIN ALARM PANEL
1-10
The system goes into the 2nd stage (or 3rd stage depending on system setting). In the
2nd stage, the following occurs:
If the visual and aural alarms are not cancelled at the 2nd stage, the system goes to
the 3rd stage and all visual and aural alarms are generated.
To stop the buzzer or cancel the emergency call, press the RESET key on the Main
Alarm Panel. The system returns to the dormant state.
1.10 How to Call a Navigation Officer
The OOW can call the Cabin Panel of the back-up officer. Use the call feature when it
is necessary to call a navigation officer to the bridge. This feature is available in all
modes. When the watch alarm is generated during a call, the call is cancelled to pro-
cess the alarm.
The ALARM LED on the called Cabin Panel lights (red) and the Cabin Panel’s buzzer
sounds.
To call a navigation officer do the following.
1. Press the ENT/CALL key to show the following window.
2. Use the CursorPad to select the navigation officer to call.
3. Press the ENT/CALL key to start the call. The called Cab-
in Panel’s ALARM LED lights and the panel’s buzzer
sounds.
4. To stop the call, press the ENT/CALL key again.
Main Alarm Panel presents a visual alarm and sounds its buzzer.
Timer Reset Panel flashes its ALARM LED and sounds its buzzer.
• Cabin Panel:
Captain’s room: ALARM LED lights and buzzer sounds.
Backup officer (selected on BNWAS display): ALARM LED lights and buzzer
sounds.
Other backup officer: No action
Public cabin: ALARM LED lights and buzzer sounds.
Flash Beacon flashes or is OFF (depending on DIP SW setting).