Furuno BR-500 Medical Alarms User Manual


 
1. MAIN ALARM PANEL
1-6
3. If the equipment connected to the system is not operated during the PREWARN-
ING, the 1st stage visual and aural alarms begin.
4. If the equipment connected to the system is not operated within 15 seconds, the
2nd stage visual and aural alarms begin.
Note: The alarm cannot be stopped from a Timer Reset Panel at this point.
Main Alarm Panel releases 15-second visual (in red) and audible alarms
Timer Reset Panel flashes its ALARM LED 15 seconds and sounds its buzzer 15
seconds
Flash Beacon flashes
Main Alarm Panel shows a 90-180-second visual alarm (in red) and sounds its
buzzer 90-180 seconds
Timer Reset Panel flashes its ALARM LED 90-180 seconds and sounds its buzzer
90-180 seconds
• Cabin Panel:
Captain selected as a backup navigator: ALARM LED lights and buzzer
sounds, 90-180 seconds each
Backup officer (selected on BNWAS display): ALARM LED lights and buzzer
sounds, 90-180 seconds each
Other backup officer: No action
Public cabin: ALARM LED lights and buzzer sounds, 90-180 seconds each
Flash Beacon flashes or is OFF (depending on DIP SW setting)
Power AC/DC
WATCH ALARM(1st stage)
Push any key.
Power AC/DC
WATCH ALARM(2nd stage)
Push [RESET] key to stop buzzer.