Patton electronic 3095 Microscope & Magnifier User Manual


 
Using a Web browser to complete Model 3095 configuration 43
Model 3095 mDSL DACS Getting Started Guide 3 • Configuring the DACS for operation
Figure 22. System Clocking Configuration window
3. Set the Fallback Reference to
internal(200)
if you have no other T1/E1 Wan links for connection to the
3095. Otherwise select the appropriate Wan port under
Fallback Reference.
4. Click on
Submit Query.
\
Figure 23. mDSO Port Configuration window
Activating the mDSL modems
Before data transmission can occur, the internal mDSL modems must be activated. Do the following to acti-
vate the modems:
1. Click on
mDSL on the Configuration Menu.
2. If you have 16 mDSL modems, click on
Activate All Available Ports. Otherwise, you may select one of the
four groups of mDSL modems, e.g., Activate Port 5 - 8, or you may individually select any mDSL modem
in the table. Activate an individual mDSL modem by selecting
connect(1)
in the pull-down menu under
Desired State. After you have activated all desired modems, click on Submit Query.