2 • Hardware installation Model 3095 mDSL DACS Getting Started Guide
24 Cable installation
2. Rotate the power cable retainer clip so it secures the power cable plug in the IEC-320 connector as shown
in figure 6.
Figure 6. Power cable retainer clip
3. Repeat steps 1 and 2 to install the remaining power cable.
Installing the power cables—DC Power Supply
This section describes installing the DACS for using DC power. Do not connect the remaining end of the
power cables to the DC power source. For the DC power source, the DACS is equipped with a two-position,
screw-down terminal block.
1. Connect the earth ground of the DC source to the grounding stud on the DACS as described in the fol-
lowing section “Grounding the Model 3095—AC and DC Power Supplies”.
2. Strip back the insulation on each of the wires approximately 1/4-inch.
3. Insert the stripped end of the positive lead into the "+DC input" of the terminal block. Tighten the screw
until the power lead is firmly fastened. Repeat the procedure for the negative lead, using the "-DC input"
of the terminal block. Make sure that all strands of the wire are captured and that there is no exposed wire.
Use copper conductors between AWG 12 - 18 only.
While looking into the DC power connector, the +DC input is on the right and
the -DC input is on the left (see figure 7).