Mitsubishi Electronics MR-MC241 Sleep Apnea Machine User Manual


 
7 - 88
7. AUXILIARY FUNCTION
(b) Details concerning system status bits
Abbreviation Signal name Function details
LOGO Log operation being
performed
[Function]
Notifies that log is now being taken.
[Operation]
<Conditions for turning on>
The log command signal (LOGC) was turned on.
<Conditions for turning off>
The log command signal (LOGC) was turned off.
LOGRF Reading of log data
complete
[Function]
Notifies that reading of log data was completed normally.
[Operation]
<Conditions for turning on>
Reading of log data is completed normally.
<Conditions for turning off>
Entered reading of data because the log command signal (LOGC) was turned on.
Reading of log data command signal (LOGR) was turned off.
LOGRE Reading of log data error [Function]
Notifies that reading of log data was not completed normally.
[Operation]
<Conditions for turning on>
Reading of log data command signal (LOGR) was turned on while log (LOGO: ON)
was being taken.
Reading of log data command signal (LOGR) was turned on with a reading of log data
page number set outside page number limits.
<Conditions for turning off>
Reading of log data command signal (LOGR) was turned off.
LOGIF Log data initialization is
complete
[Function]
Notifies that log data initialization was completed normally.
[Operation]
<Conditions for turning on>
Initialization of log data is completed normally.
<Conditions for turning off>
Initialization of data entered through turning the log data initialization command signal
(LOGI) on.
The log data initialization command signal (LOGC) was turned off.
LOGIE Log data initialization
error
[Function]
Notifies that log data initialization was not completed normally.
[Operation]
<Conditions for turning on>
Log data initialization command signal (LOGI) was turned on while log operation being
performed signal (LOGO) was turned on.
<Conditions for turning off>
The log data initialization command signal (LOGC) was turned off.