6. APPLICATION FUNCTIONS
POINT
• The value for continuous operation to control data at the start of operation at
the continuous operation to torque control point is valid.
• Continuous operation to torque control data that is changed during the
operation of a continuous operation to torque control point becomes valid at
the operation of the next continuous operation to torque control point.
• The press time is the time passed since torque within the torque settle width is
continuously output during the torque settle waiting time. (The press time
continues even if a value outside the torque settle width occurs part of the
way through.)
• When a value outside of the range is set to continuous operation to torque
control data and automatic operation is startup, a continuous operation to
torque control setting error (operation alarm 5E, detail No.01 to 05) occurs,
and the operation is not started.
• When a press limit position is set in the opposite direction of the position
control travel direction, a continuous operation to torque control error
(operation alarm 5D, detail No.05) occurs, and the operation is not started.
• When a press limit position is set before the positioning data, a continuous
operation to torque control error (operation alarm 5D, detail No.08) occurs,
and the operation is not started. (A press limit position is not reached during
position control mode)
• The press limit position is determined by the current feedback position. When
the press limit position is reached during continuous operation to torque
control, a continuous operation to torque control error (operation alarm 5D,
detail No.03) occurs, and stops at the position where the press limit position
was exceeded.
• When target torque is reached during acceleration, it is determined that press
has started and the press time measurement begins.
• When the continuous operation to torque control switching position is in the
opposite direction of the movement direction, the continuous operation to