Mitsubishi Electronics MR-MC241 Sleep Apnea Machine User Manual


 
7 - 27
7. AUXILIARY FUNCTION
7.9 Parameter backup
POINT
When there are a lot of changing parameters of the position board and servo
amplifier and the parameter changing time effects the system startup, saving
parameters in the flash ROM of the position board by this function can
shorten the time of system startup.
(1) Flash ROM parameter backup
The contents of the parameter data area in the position board can be backed up to the flash ROM. When
executing flash ROM parameter read (system command code: 0004h) at system preparation completion
(system status code: 0001h), backup the parameter in the flash ROM with this function. Execute parameter
backup in the flash ROM in the following procedure.
Note. At factory shipment, the initial value is set to each parameter.
No
Flash ROM transfer
ID setting
Yes
Turn on flash ROM transfer
execution (FTS).
End
Turn on flash ROM transfer
preparation (FTR).
No
Yes
Turn off flash ROM
transfer execution (FTS).
Turn off flash ROM
transfer preparation (FTR).
Parameter setting
* Transfer parameters to flash ROM
No
* Set A51E to flash ROM transfer ID.
Start
Yes (Note 8,9)
* Set parameters in the position board using the parameter
write function.
sscSaveAllParameterToFlashROM function
Flash
ROM transfer
preparation completion?
(FROK=ON?)
Flash ROM
transfer error?
(FSNG = OK?)
Flash ROM transfer
complete?
(FSOK=ON?)
Check whether the number
of write accesses to flash
ROM error (system alarm
36) occurs.