Emerson Process Management 3051N Sleep Apnea Machine User Manual


 
Reference Manual
00809-0100-4808, Rev CA
June 2008
A-3
Rosemount 3051N
FIGURE A-1. HART Communicator Typical Abbreviated Menu Tree for Rosemount 3051.
1 DEVICE
SETUP
2PV
3AO
4LRV
5URV
1 PROCESS
VARIABLE
2 DIAGNOSTICS
AND SERVICE
3 BASIC SETUP
4DETAILED
SETUP
5Review
Online
Menu
1Pressure
2 Percent Range
3 Analog Output
4Sensor
Temperature
1TEST DEVICE
2 Loop Test
3 CALIBRATION
1Self Test
2Status
1 RERANGE
2 TRIM ANALOG
OUTPUT
3SENSOR TRIM
7METER OPTS.
1SENSORS
2 SIGNAL
CONDITION
3OUTPUT
CONDITION
4 DEVICE
INFORMATION
4 RECALL
FACTORY TRIM
1 Keypad Input
2 Apply Values
1 Digital-to-Analog Trim
2 Scaled D/A Trim
1 Zero Trim
2Lower Sensor Trim
3 Upper Sensor Trim
4Sensor Trim
Calibration Type
5 Sensor Trim Points
1Sensor Trim
2 Analog Output Trim
1 Keypad Input
2 Apply Values
1Date
2Descriptor
3 Message
4 Write Protect
1Tag
2Unit
3 RANGE VALUES
4 DEVICE INFO
5Transfer Function
6Damp
1 Meter Type
2 CUSTOM
METER SETUP
1 PRESSURE
SENSOR
2 TEMP SENSOR
1Sensor Temp
2 Temperature Unit
1Sel Dec Pt Pos
2CM Upper Value
3CM Lower Value
4CM Units
5 CM xfer function
1 PROCESS VARIABLE
2 SENSOR SERVICE
3Unit
1Pressure
2% Range
3Sensor Temp
1SENSOR
TRIM
2 Recall
Factory
Tr im
1 Zero Trim
2Lower
Sensor Trim
3 Upper
Sensor Trim
4 Sensor Trim
Calibration
Ty pe
5Sensor Trim
Points
1PROCESS
VARIABLE
2 RANGE
VALUES
3Unit
4Transfer Func
5Damp
6Snsr Temp Unit
7ALM/SAT
LEVELS
1PROCESS
VARIABLES
2 ANALOG
OUTPUT
3 HART OUTPUT
4METER
OPTIONS
1 FIELD DEVICE
INFO
2SENSOR INFO
3Self Test
4 DIAPHRAGM
SEALS INFO
1Pressure
2% Range
3Snsr Temp
1Keypad Input
2Apply Values
1High Alarm
2Low Alarm
3 High Saturation
4 Low Saturation
5AO Alarm Type
6 Alarm/Sat Type
1Pressure
2 % Range
3Analog Output
4Sensor Temp
1 Loop Test
2 Digital-to-Analog Trim
3 Scaled D/A Trim
4AO Alarm Type
1 Poll Address
2 Nos. of Req. Pream.
3Burst Mode
4 Burst Option
1 Meter Type
2 CUSTOM METER
SETUP
3 Custom Meter Value
1Measurement Type
2 Mod. Config. Type
3 Isolator Material
4 Fill Type
5Proc. Conn. Type
6 Proc. Conn. Material
7 O-Ring Material
8 Drain/Vent Material
1 Sel. Dec. Pt. Pos.
2CM Upper Value
3CM Lower Value
4CM Units
5 CM xfer function
1Tag
2Date
3Descriptor
4 Message
5 Model
6 Write Protect
7 Local Keys
8 REVISION #S
9Final Assy #
10 Device ID
11 Distributor
1Univ.
Rev.
2Fid. Dev.
Rev.
3 S/W Rev.
1 # of Diaphr. Seals
2 Diaphr. Seal Type
3 Diaphr. Seal Fill
4Diaphr. Material
NOTE
“3051” will appear in the upper left of the
communicator screen when this menu tree is valid.