Net Oil Computer Supplement 57
Operation Mode – NOC
Troubleshooting IndexSeries 3000 MenusNOC Operation
5.4 Changing modes
Changing from Well Test mode to Continuous mode, or from Continuous mode to Well Test mode,
affects current measurement and data collection. To change modes, follow the instructions in this
section.
To change from Well Test mode to Continuous mode:
1. If a well test is running, it will be stopped automatically when the mode is changed.
2. Perform all required or desired recalculations.
3. Well test data will be unavailable from the display while the system is in Continuous mode.
Record all required or desired well test data to an external system.
4. Change
Mode of Operation to Continuous Mode.
To change from Continuous mode to Well Test mode:
1. If desired, save an archive record.
2. Perform all required or desired recalculations.
3. Continuous mode data will be unavailable from the display while the system is in Well Test
mode. Record all required or desired data to an external system.
4. Change
Mode of Operation to Well Test Mode.
Table 5-9 Recalculation parameters – Continuous mode measurement
Parameter Configurable? Definition
Original Ref Temp
(1)
(1) If the value was changed during the measurement period, the value displayed here is the value in use when the archive record was
saved.
No Reference temperature for NOC calculations applied during data
collection
Recalc Reference Temp Yes Reference temperature to used for recalculation
Orig Water Density
(1)
No Reference density of water applied during data collection
Recalc Water Density Yes Reference density of water to be used for recalculation
Original Oil Density
(1)
No Reference density of oil applied during data collection
Recalc Oil Density Yes Reference density of oil to be used for recalculation
Original Press Comp Oil
(1)
No Pressure compensation factor for oil applied during data collection
Recalc Press Comp Oil Yes Pressure compensation factor for oil to be used for recalculation
Original Ref Pressure
(1)
No Reference pressure applied during data collection
Recalc Ref Pressure Yes Reference pressure applied to be used for recalculation
Original Gas Ref
Density
(1)
No Reference density of gas from this well applied during data collection
Recalc Gas Ref Dens Yes Reference density of gas to be used for recalculation
Original Factor for Oil
(1)
No Shrinkage factor for oil applied during data collection
Recalc Factor for Oil Yes Shrinkage factor for oil to be used for recalculation
Original Factor for Water
(1)
No Shrinkage factor for water applied during data collection
Recalc Factor for Water Yes Shrinkage factor for water to be used for recalculation