Emerson MMI-20011276 Pacemaker User Manual


 
Net Oil Computer Supplement 51
Operation Mode – NOC
Troubleshooting IndexSeries 3000 MenusNOC Operation
5.3.1 Viewing Continuous mode measurement data
To view basic data from Continuous mode measurement, use the Quick View menu shown in
Figure 5-3. Process variables available from the Quick View menu are listed in Table 5-6.
Note: You can also read Continuous mode measurement data via Modbus or report actual and
average process variables by assigning them to a milliamp or frequency output.
To view more detailed data, use the View Production Measurement menu shown in Figure 5-3. This
screen provides:
Production data for several other process variables, as listed in Table 5-7
TMR data, as listed in Table 5-8
Table 5-6 Quick View data – Continuous mode
Process variable Definition
Average net oil rate Average net oil flow rate, calculated from the beginning of Continuous mode measurement or
from the last reset. May or may not include oil carry-over, depending on TMR configuration.
Net oil total Total net oil, by volume, calculated from the beginning of Continuous mode measurement or
from the last reset. May or may not include oil carry-over, depending on TMR configuration.
Average water cut Average water cut value, calculated from the beginning of Continuous mode measurement or
from the last reset. May be either density-based or from the water cut monitor, depending on
water cut configuration.
Average gross rate Average flow rate of production fluid, calculated from the beginning of Continuous mode
measurement or from the last reset. May or may not include TMR carry-over data, depending
on TMR configuration. Does not include gas data.
Gross total Total production fluid, by volume, calculated from the beginning of Continuous mode
measurement or from the last reset. May or may May or may not include TMR carry-over data,
depending on TMR configuration. Does not include gas data.
Average/total since Timestamp of beginning of Continuous mode measurement or the last Reset All.
Test time elapsed Hours and minutes since this Continuous mode measurement period was started
Transient bubble time Hours and minutes that TBR has been active
Water cut overrange (Water cut monitor only) Hours and minutes that the water cut has been above the configured
External Water Cut Limit
Total paused time Hours and minutes that measurement has been paused
Transient mist time Hours and minutes that TMR has been active