Emerson MMI-20011276 Pacemaker User Manual


 
40 Micro Motion
®
Series 3000 MVD Transmitters
Configuring the NOC Application
Figure 4-12 Density determination for oil – Water cut entry screen
14. Enter the water cut measured in Step 7, then press
SAVE.
15. Select
Calculate at Ref, then press SEL. The NOC application uses this water cut data to
convert the observed oil density to dry oil density at reference temperature, and displays a
screen similar to Figure 4-13. This screen also displays the stored value for oil density at
reference temperature, and the date and time at which this value was stored.
To replace the stored value with the new value, press
SAVE, then press YES to confirm.
To discard the data from this procedure, press
EXIT. You will be returned to the Procedure
Selection screen. From this point you can repeat the density determination procedure or
press
EXIT to move up the menu and return to other functions.
Figure 4-13 Density determination for oil – Procedure results
Enter Water Cut
Water Cut
xx.xx %
Apply to Sample Taken
dd-mmm-yy hh:mm
Calculate at Ref
CHG EXIT
Oil Density
Oil Density @ Ref
x.xxxx g/cm3
Oil Density at
dd-mm-yy hh:mm
Current Dens @ Ref
x.xxxxx g/cm3
Current Dens Saved
dd-mm-yy hh:mm
SAVE HELP EXIT