Net Oil Computer Supplement 27
Configuring the NOC Application
NOC Overview NOC ConfigurationUsing the DisplayBefore You Begin NOC Overview NOC ConfigurationUsing the DisplayBefore You Begin NOC Overview NOC ConfigurationUsing the DisplayBefore You Begin NOC Overview NOC ConfigurationUsing the DisplayBefore You Begin
9. If desired, configure the severity level of the NOC status alarms. The status alarms listed in
Table 4-3 indicate specific states of the NOC application. Like all other status alarms on the
Series 3000 platform, they can be configured for three different severity levels – Ignore, Info,
and Fault. To configure the NOC status alarms, see the instructions in the manual entitled
Series 3000 MVD Transmitters and Controllers: Configuration and Use Manual.
Table 4-3 NOC status alarms
Category
Alarm
number
Maintenance
menu listing Description
Alarm severity
Affected by fault
timeoutDefault
User
config?
Electronics A136 Power Outage The power was off for
at least 30 seconds.
Info Yes No
Process A138 TBR Active The drive gain has
exceeded the
configured TBR
threshold.
Info Yes No
A139 Water Cut
Overrange
The water cut
measured by the
water cut monitor is
above the configured
External Water Cut
Limit.
Info Yes No
A140 TMR Active The drive gain has
exceeded the
configured TMR
threshold.
Info Yes No
Configuration A137 Measurements
Paused
Continuous mode
measurements have
been paused for
more than 15
minutes.
Info Yes No