Dell E20S001 Microscope & Magnifier User Manual


 
Error Code Message Information
Action Re-configure system to the minimum supported configuration. If
issues persists, contact support.
TMP0118
Message The system inlet temperature is less than the lower warning
threshold.
LCD Message System inlet temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0119
Message The system inlet temperature is less than the lower critical threshold.
LCD Message System inlet temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0120
Message The system inlet temperature is greater than the upper warning
threshold.
LCD Message System inlet temperature is outside of range.
Details Ambient air temperature is too warm or one or more fans may have
failed.
Action Check the system operating environment and review event log for fan
failures.
TMP0121
Message The system inlet temperature is greater than the upper critical
threshold.
LCD Message System inlet <
name
> temperature is outside of range. Check Fans.
Details Ambient air temperature is too warm or one or more fans may have
failed.
Action Check the system operating environment and review event log for fan
failures.
VLT0204
Message The system board <
name
> voltage is outside of the allowable range.
LCD Message System board voltage is outside of range.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
161