Error Code Message Information
AMP0302
Message The system board <
name
> current is greater than the upper warning
threshold.
Details System board <
name
> current is outside of the optimum range.
Action
1. Review system power policy.
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see Getting Help.
AMP0303
Message The system board <
name
> current is greater than the upper critical
threshold.
LCD Message System board <
name
> current is outside of range.
Details System board <
name
> current is outside of the optimum range.
Action
1. Review system power policy.
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see Getting Help.
ASR0000
Message The watchdog timer expired.
Details The operating system or an application failed to communicate within
the time-out period.
Action Check the operating system, application, hardware, and system event
log for exception events.
ASR0001
Message The watchdog timer reset the system.
Details The operating system or an application failed to communicate within
the time-out period. The system was reset.
Action Check the operating system, application, hardware, and system event
log for exception events.
ASR0002
Message The watchdog timer powered off the system.
Details The operating system or an application failed to communicate within
the time-out period. The system was shut down.
Action Check the operating system, application, hardware, and system event
log for exception events.
147