Dell E20S001 Microscope & Magnifier User Manual


 
Error Code Message Information
5. If the issue persists, see Getting Help.
FAN0000
Message Fan <
number
> RPM is less than the lower warning threshold.
Details Fan operating speed is out of range.
Action Remove and reinstall the fan. If the issue persists, see Getting Help.
FAN0001
Message Fan <
number
> RPM is less than the lower critical threshold.
LCD Message Fan <
number
> RPM is outside of range. Check fan.
Details Fan operating speed is out of range.
Action Remove and reinstall the fan. If the issue persists, see Getting Help.
FAN1201
Message Fan redundancy is lost.
LCD Message Fan redundancy is lost. Check fans.
Details Fan has failed.
Action Remove and reinstall failed fans or install additional fans.
HWC1001
Message The <
name
> is absent.
LCD Message The <
name
> is absent. Check hardware.
Details The absent device may be necessary for proper operation. System
functionality may be degraded.
Action Reinstall or reconnect the hardware.
HWC2003
Message The storage <
name
> cable is not connected, or is improperly
connected.
LCD Message Storage <
name
> cable or interconnect failure. Check connection.
Details The cable may be necessary for proper operation. System
functionality may be degraded.
Action Check if the cable is present, then reinstall or reconnect.
HWC2005
Message The system board <
name
> cable is not connected, or is improperly
connected.
LCD Message System board <
name
> cable connection failure. Check connection.
Details The cable may be necessary for proper operation. System
functionality may be degraded.
151