Dell E20S001 Microscope & Magnifier User Manual


 
Error Code Message Information
ASR0003
Message The watchdog timer power cycled the system.
Details The operating system or an application failed to communicate within
the time-out period. The system was power-cycled.
Action Check the operating system, application, hardware, and system event
log for exception events.
BAT0002
Message The system board battery has failed.
LCD Message The system board battery has failed. Check battery.
Details The system board battery is either missing or bad.
Action See Getting Help.
BAT0017
Message The <
name
> battery has failed.
LCD Message The <
name
> battery has failed. Check battery.
Details The <
name
> battery is either missing, bad, or unable to charge due to
thermal issues.
Action Check system fans. If the problem persists, see Getting Help.
CPU0000
Message CPU <
number
> has an internal error (IERR).
LCD Message CPU <
number
> has an internal error (IERR).
Details System Event Log and Operating System Logs may indicate that the
exception is external to the processor.
Action Review System Event Log and Operating System Logs. If the issue
persists, see Getting Help.
CPU0001
Message CPU <
number
> has a thermal trip (over-temperature) event.
LCD Message CPU <
number
> has a thermal trip. Check CPU heat sink.
Details The processor temperature increased beyond the operational range.
Action Review the logs for fan failures. If no fan failures are detected, check
inlet temperature (if available) and reinstall processor heat sink. If the
problem persists, see Getting Help.
CPU0005
Message CPU <
number
> configuration is unsupported.
LCD Message CPU <
number
> configuration is unsupported. Check CPU or BIOS
revision.
Details System is unable to boot or may run in a degraded state.
148