Error Code Message Information
PSU1201
Message Power supply redundancy is lost.
Details The power supply tries to operate in a degraded state. System
Performance and power redundancy may be degraded or lost.
Action Check input power. Reinstall the power supply. If the issue persists,
see Getting Help.
PSU1204
Message The power supplies are not redundant. Insufficient resources to
maintain normal operations.
LCD Message PSU redundancy degraded. Check PSU cables.
Details The current power operational mode is non-redundant because of a
power supply exception, a power supply inventory change, or a
system power inventory change.
Action Check the event log for power supply failures. Review system
configuration and power consumption.
PWR1004
Message The system performance degraded because power capacity has
changed.
Details The system may power down or operate in a performance degraded
state.
Action Check the event log for power supply failures. Review system
configuration and power consumption and upgrade or install power
supplies accordingly.
PWR1005
Message The system performance degraded because the user-defined power
capacity has changed.
Details The user-defined power settings have affected system operation.
Action If unintended, review system configuration changes and power
policy.
PWR1006
Message The system halted because system power exceeds capacity.
LCD Message System power demand exceeds capacity. System halted.
Details The system halted because system power exceeds capacity.
Action Review system configuration, upgrade power supplies or reduce
system power consumption.