Pelco Net350 Pacemaker User Manual


 
C2907M-D (4/05) 85
CONNECTING PELCONET TO A CM6800 AND KBD200A FOR REMOTE CONTROL
Refer to Figure 63. This configuration lets an operator view and control cameras with a remote KBD200A keyboard. All settings are done in the
CM6800 manager program or through a CM6800 menu. Note the following:
Port 2 defaults to ASCII and RS-232.
Ports 7 and 8 can be set to ASCII and RS-232 by using the CM6800 manager program (refer to Figure 63) or by using a CM6800 menu (refer
to Figure 60).
Pelco recommends using Port 2.
Figure 63. Using PelcoNet with CM6800 and KBD200A to Provide Remote Control
Vi deoIn
75
Audio I/O
Powe r
ETHERNET
CONNECTION
TO NETWORK
(LAN/WAN)
TRANSMITTER
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
2-RX
3-TX
5-GND
SPECTRA
COAXITRON
PROTOCOL
PELCONET TRANSPARENT
DATA PORT
2 RXD..............................
3 TXD..............................
5 GND............................
CM6800E-48X8
COM 2
8 TXD
1 RXD
5 GND
6800 MATRIX COM 2
PORT SETTINGS:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
NOTE: FIRMWARE VER 4.0 OR LATER REQUIRED. SET KEYBOARD DIP SWITCHES - SWITCH
6 ON, SWITCHES 5 AND 8 OFF, SWITCHES 1 - 4 FOR ADDRESS ACCORDING TO THE
TABLE IN THE KBD200A MANUAL.
Vi deoOu t
75
Audio I/O
Powe r
RECEIVER
ETHERNET CONNECTION
TO NETWORK (LAN/WAN)
12 V
TX(-)
RX(-)
KBD200A
STRAIGHT
CABLE
PV140 ORDERED
SEPARATELY
12 VAC
1
2
3
4
8
7
6
5
GND
RX(+)
TX(+)
2-RX
3-TX
5-GND
RJ-45 WALL BLOCK
AND STRAIGHT
CABLE SUPPLIED
PELCONET CM6800 ASCII SETUP
TRANSPARENT DATA PORT
USING INTERNET EXPLORER
SET TRANSPARENT DATA
PORT SETTINGS:
PELCONET REMOTE KBD200A ASCII MODE SETUP
COM2:
RS232
COM1:
RS232/422/485
COM2:
RS232
COM1:
RS232/422/485
TRANSPARENT DATA PORT
USING INTERNET EXPLORER, SET
TRANSPARENT DATA SETTINGS
ON BOTH PELCONET RECEIVER
AND TRANSMITTER:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1