Pelco Net350 Pacemaker User Manual


 
40 C2907M-D (4/05)
Connect on alarm Off The alarm functions would have little effect without automatically triggering corresponding actions. Select On for
automatic connection to the video receiver’s IP address. The idea is to provide a remote monitoring station with live
video in case of an alarm. (If you want both motion and alarm input to activate an alarm, set this field to On. If set to
motion only, motion alarms will activate an alarm but no input alarms will be recognized.)
This feature can be useful even for many applications not related to alarm conditions. One example is a video-
equipped door entry system: when the doorbell is pressed, a contact closes and the connected transmitter automat-
ically connects to a receiver. Full duplex audio can provide verbal communication, while the relay output can open
the door remotely.
Select Follows input to specify that the connection remain as long as the alarm is active. (If Follows input is set,
motion will not activate an alarm.) Select Follows motion alarm to specify that the alarm will turn on when
motion is detected and turn off 10 seconds after motion is no longer detected. (If Follows motion alarm is set,
input will not activate an alarm.)
Number of video
receiver address
1 The NET350 can store up to 10 different alarm IP addresses. When an alarm occurs, a connection is established to
the first address. Up to 10 separate addresses can be added should the first address not accept the call.
Use the pull-down menu to select how many additional addresses to contact, if necessary. (Add the IP addresses in
the next field.)
Live video receiver
IP address
0.0.0.0 Enter the IP addresses (10 maximum) of the receivers to be notified in the event of an alarm.
Remote receiver
password
N/A Enter the password for the remote unit if it is protected by a User or Live password.
Live video
auto-connect
Off Select On if at each restart an active connection should be set up automatically to the receiver’s IP address. The
auto-connect feature guarantees an active connection to the receiver’s alarm IP address even after connection
breakdown or network failures. As soon as communication is restored, the connection is reinstated. On a receiver,
this feature is enabled to establish a connection to a transmitter automatically.
Configuration
Item
Default
Setting Description
WARNING: Setting a User level password on a transmitter can cause complications on the receiver side in a
box-to-box configuration. To avoid this, on the receiver’s Alarm Settings configuration page enter the transmit-
ter’s IP address and user password in the appropriate fields (live video receiver IP address and remote receiver
password). If no User level password is set on the transmitter, then the receiver needs no setup.