FLANGE_MTL 69 Type of material of the flange. See flange material codes.
0 = Carbon Steel
2 = 316 Stainless Steel
3 = Hastelloy C
4 = Monel
24 = Kynar
252 = "Unknown"
253 = "Special"
FLANGE_TYPE 68 Type of flange that is attached to the device.
12 = Conventional (Traditional)
13 = Coplanar
14 = Remote Seal
15 = Level; 3 in. 150 lbs.
16 = Level; 4 in. 150 lbs.
17 = Level; 3 in. 300 lbs.
18 = Level; 4 in. 300 lbs.
19 = Level; DN 80, PN 40
20 = Level; DN 100, PN 40
21 = Level; DN 100, PN 10/16
22 = Level; 2 in. 150 lbs.
23 = Level; 2 in. 300 lbs.
24 = Level; DN 50, PN 6
25 = Level; DN 50, PN 40
252 = "Unknown"
253 = "Special"
FREE_TIME 25 Percent of the block processing time that is free to process additional blocks.
FREE_SPACE 24 Percent of memory available for further configuration. Zero in a preconfigured device.
GRANT_DENY 14 Options for controlling access of host computers and local control panels to operating,
tuning, and alarm parameters of the block. Not used by device.
HARD_TYPES 15 The types of hardware available as channel numbers.
hardware_rev 52 Hardware revision of the hardware that has the resource block in it.
LIM_NOTIFY 32 Maximum number of unconfirmed alert notify messages allowed.
MANUFAC_ID 10 Manufacturer identification number – used by an interface device to locate the DD file for
the resource.
MAX_NOTIFY 31 Maximum number of unconfirmed alert notify messages possible.
MEMORY_SIZE 22 Available configuration memory in the empty resource. To be checked before
attempting a download.
message_date 57 Date associated with the MESSAGE_TEXT parameter.
message_text 58 Used to indicate changes made by the user to the device's installation, configuration,
or calibration.
MIN_CYCLE_T 21 Time duration of the shortest cycle interval of which the resource is capable.
MODE_BLK 05 The actual, target, permitted, and normal modes of the block:
Target: The mode to “go to”
Actual: The mode the “block is currently in”
Permitted: Allowed modes that target may take on
Normal: Most common mode for actual
NV_CYCLE_T 23 Minimum time interval specified by the manufacturer for writing copies of NV parameters
to non-volitile memory. Zero means it will never be automativally copied. At the end of
NV_CYCLE_T, only those parameters which have changed need to be updated in
NVRAM.
O_RING_MTL 69 Type of material of the flange o-rings. See O-ring material codes.
10 = PTFE (Teflon TM)
11 = Viton
12 = Buna–N
13 = Ethyl–Prop
252 = "Unknown"
253 = "Special"
output_board_sn 53 Output board serial number.
Parameter
Index
Number
Description