Polycom ViewStation EX Microscope & Magnifier User Manual


 
ViewStation EX, ViewStation FX, and VS4000 API Guide
58 www.polycom.com
farloop <on|off>
Description
This command turns the far-end loop on or off, when in a call.
on Turns the option on.
off Turns the option off.
Example
farloop on
User Interface Screen Location
System Info>Diagnostics>Far End Loop
farnametimedisplay <set|get> [0-9999]
farnametimedisplay set ["time"]
farnametimedisplay set
farnametimedisplay get
Description
This option displays the length of time the far-site name is to be
displayed.
set Sets the display time when followed by the parameter
time. If you want to erase the current setting, omit time.
The far-site name is displayed by default for 15
seconds. farnametimedisplay set displays the far-site
name until the call is ended.
get Displays the current setting.
0-9999 Time value specified in seconds.
farloop