ViewStation EX, ViewStation FX, and VS4000 API Guide
© Polycom, Inc. 2003 123
rs232<mode|flowcontrol|baud|>
Subcommands
rs232 mode <passthru|control|get>
rs232 flowcontrol <none|hardware|get>
rs232 baud <1200| 2400|9600|14400|19200|38400|
57600|115200|get>
Description
This command configures and monitors the RS-232 port. For more
detailed information about the RS-232 interface, see “Using the
RS-232 Interface,” on page 3 of this manual.
mode passthru Sets the RS-232 port to passthru mode.
mode control Sets the RS-232 port to control mode.
mode get Displays the current mode setting (passthru or
control).
flowcontrol noneSets the RS-232 hardware flow control to none.
flowcontrol hardware
Sets the RS-232 hardware flow control to
hardware.
flowcontrol get Displays the current flowcontrol setting (none or
hardware).
baud <1200..115200>
Sets the RS-232 port baud rate. Supported baud
rates are 1200, 2400, 9600, 14400, 19200, 38400,
57600,115200.
Examples
rs232 mode passthru
rs232 baud 9600
rs232 flowcontrol hardware
rs232